SPECIFICATION

Classification criteria classification
Size 15.8 x 11.4 x 18.5 in. / 40.0 x 29.0 x 47.0 cm
Weight 17.6 lb / 8 kg
Humidity 5 ~ 95% RH (non-condensing)
IP Rating • IP65 for pumped models
• IP67 for diffusion models
Alarms Red/yellow/green LED alarm; buzzer alarm 108 dBA @ 1 m; on-screen indication of alarm conditions
Battery Rechargeable Li-ion battery (3.7V / 26.4 Ah)
Running Time 8 weeks for low-power model; other models vary by configuration
Radio Module & Range • Bluetooth Low Energy: RMBLEC, up to 16.4 ft. / 5 m
• Mesh: RM900A, 984 ft. / 300 m (868-900 MHz) or RM2400, 492 ft. / 150 m (2.4 GHz )
• Wi-Fi: RMWIFIC, up to 164 ft. / 50 m
WIRELESS • Bluetooth Low Energy Module (BT 4.2 / 5.0), 2.4 GHz, in default
• Mesh Module: IEEE 802.15.4 868 MHz / 915MHz /2.4 GHz (optional)
• Wi-Fi Module: 802.11 b/g/n 2.4 GHz (optional)
Data Logging Complete gas sensors and instrument information for at least 4 months at one minute intervals
Certifications cETLus Class I Division 1; Group A, B, C, D; T4;
IEC EX/ATEX
I M1 Ex ia I Ma
II 1G Ex ia da IIC T4 Ga
I M1 Ex ia I Ma
II 2G Ex ia da db IIC T4 Gb
1G Ex ia da IIC T4 Ga
Warranty • Two years on LEL, CO, H2S, and O2 sensors
• One year on other sensors

EXTERNAL PORTS

Classification criteria classification
Safe Area Charge Port Battery charger input 6 VDC 3 A typical; connect to AC/DC adaptor
Field Charge Intrinsically safe line power supply input to extend instrument runtime (low-power model only)
RAEMET PORT Port to RAEMet wind sensor (optional)
Analog/Switch Input Port • 4-20 mA signal input,
• X1 channel/switch on/off signal input
• X1 channel (optional)
ON/OFF SWITCH OUTPUT Max 20 V / 120 mA, SPDT Normal Open, X3 channels for external ports (optional). Refer to User Guide for complete details.

RAEMet SPECIFICATIONS (Optional)

Classification criteria classification
Wind Speed Range: 0 to 20 m/s (0 to 44 mph)
Start Speed: 0.1 m/s (0.22 mph)
Wind Direction Range: 360°
Temperature -20 ~ 60 °C (-4 ~ 140 °F)
Resolution 0.1 °C (1.8 °F)
Humidity 10 ~ 95% RH
Resolution 1% RH
Compass Resolution 1°
Power Power supplied by the AreaRAE Plus

Sensor List

SENSOR Measuring Range
IR 0 - 100% LEL / 0 - 100% vol
LEL 0 - 100% LEL
CO2 0 - 5% vol.
CO2 (EXT. RANGE) 0 - 100% vol
VOC 0 - 2,000 ppm
CO 0 - 500 ppm
CO (EXT. RANGE) 0 - 2,000 ppm
CO (H2 RESISTANT) 0 - 1,000 ppm
H2S 0 - 100 ppm
H2S (EXT. RANGE) 0 - 1,000 ppm
SO2 0 - 20 ppm
O2 0 - 30% vol.
NO 0 - 250 ppm
NO2 0 - 20 ppm
HCN 0 - 50 ppm
NH3 0 - 100 ppm
Cl2 0 - 50 ppm